Henan Sanqiang Medical Equipment Liability Co.,Ltd
Current location:Home > Products > Ethylene oxide sterilizer
Ethylene oxide sterilizer

Table Top ETO Autoclave

Update time:2017-10-24

Volume (L)

23L

Sterilization room size (diameter*depth) cm

φ24*47

Shape dimension (length * width * height) cm

67×45×40

Weight (Kg)

40

Standard sterilization time (min)

0-99Adjustable hours

Sterilization temperature(℃)

50℃±3℃

Gas selection

Pure ethylene oxide gas

Power connection

220V/50Hz

Total power(KW)

1。3

Humidity during sterilization

45%-75%

Working pressure

-60kpa

Single use of ethylene oxide

30g

[air replacement] automatic ventilation, cycle ventilation 5 times, interval 15 minutes once

[automatic control system] one button start to end, automatic completion of the whole process

[display] state display temperature, humidity and pressure, sterilization time, processing time, the number of residual gas

[printer] using micro printer, print out the whole process of sterilization each minute of data, can be permanent preservation。

[humidity sensor] built-in humidity sensor automatic detection of cavity humidity, to ensure that the cavity humidity is not less than 45%RH。

[pressure sensor] built-in pressure sensor automatically detects cavity pressure, to ensure the accurate and effective pressure inside the chamber.

[temperature sensor] built-in temperature sensor, automatic detection of cavity temperature, to ensure that the cavity temperature is maintained at 50 degrees C + 3 temperature within the precise range.

[vacuum system] using oil-free vacuum pump, simple and convenient, fast vacuum speed, long service life.

[circulation device] when the water temperature in the heating tank exceeds 85 degrees, the heater should be automatically stopped heating;

[sealed door] anti pressure 200Kpa, EO gas never leak.

[humidifying system] pulse humidification under vacuum condition, ensure the humidity of the cavity is even and controllable; the humidity of the sterilizing room should be controlled within the range of relative humidity of 55% + 20%;

[] residual processing device filter on particle diameter of more than 0。3 m the filtering rate of not less than 99。5%。

[sterilization room] leak rate determination of leakage rate at no-load, sterilization room temperature constant, test pressure -50kPa, time 1H were determined under the conditions of determination of time average leakage rate less than 0。16kPa/min。

[rate] vacuum under no-load condition, atmospheric vacuum sterilizer from time to -60kPa should be less than 30min.

[automatic dosing] the first domestic sterilization chamber piercing technology, to ensure the full use of gas, zero leakage, more safe and reliable.

[heating system] adopts explosion proof electric heating device

[a variety of protective functions] with over-voltage, over temperature protection function, more safe and reliable.

[alarm system] has high temperature alarm system, ultra low pressure alarm system

[category] class II medical devices


Click refresh

Related products

Related news

Products

Contact

Sales Tel:  +86-400-672-7500

Foreign trade Tel:+86-372-5577488

Shanghai office:+86-21-68751982

Company Tel:+86-372-5577388

                       +86-372-5577588

After sale:+86-372-5577599


Contact us

WeChat subscription

WeChat service

Mobile terminal

Sales Tel: +86-400-672-7500

Foreign trade Tel: +86-372-5577488

Shanghai office: +86-21-68751982

After sale: +86-372-5577599

Company Tel: +86-372-5577388

Company Tel: +86-372-5577588


Copyright © Henan Sanqiang Medical Equipment Liability Co.,Ltd  http://en.ccsmyanmar.com/Disclaimer  
上海快3 上海快三 上海快三 上海快三 上海快三 上海快三 上海快3 上海快三 上海快3 上海快三